ICP-OES Testing Services – Multi-Element Analysis, Metal Impurity Testing & Material Composition Characterization
Shanghai Jituotech Material Technology Co., Ltd. provides professional ICP-OES (Inductively Coupled Plasma Optical Emission Spectrometry) testing services for a wide range of material systems, including polymers, chemical materials, inorganic ceramics, metals, composites, fine chemicals, and biomaterials.
ICP-OES is an instrumental analytical technique used for qualitative and quantitative elemental analysis based on characteristic emission spectra. After appropriate sample preparation, the sample is introduced into a high-temperature inductively coupled plasma, where atoms and ions are excited and emit light at characteristic wavelengths. By measuring the wavelengths and intensities of these emission lines, the elements present in a sample can be identified and quantified using calibration standards. ICP-OES Testing Services Overview
ICP-OES is a widely used analytical technique for elemental composition analysis. Its main advantages include multi-element capability, relatively high analytical throughput, broad elemental coverage, and quantitative measurement capability.
Jituotech's ICP-OES testing services address the following analytical requirements:
Which elements are present in a material? Identify or screen selected metallic and non-metallic elements.
What is the concentration of a target element? Quantify elemental concentrations or mass fractions using calibrated standards.
Does the material contain metal impurities? Determine selected metallic impurities in raw materials, intermediates, or finished products.
Are elemental compositions consistent between batches? Compare element concentrations across different batches, suppliers, or formulations.
Does the material contain the expected inorganic components? Support the analysis of inorganic fillers, metallic components, catalyst residues, and functional elements.
Does the product meet specific elemental quality requirements? Perform quantitative analysis according to target elements, analytical limits, and applicable methods.
ICP-OES Service Information
Item
Service Information
Analytical technique
ICP-OES
Instrument model
Agilent 5110
Analytical principle
Characteristic elemental emission spectra
Analytical targets
Metals and selected non-metallic elements
Analytical capability
Qualitative and quantitative multi-element analysis
Sample forms
Solid and liquid
Sample quantity
100 mg–5 g as recommended on the original service page; actual requirements depend on sample type and preparation
Sample preparation
Dissolution, acid digestion, or other suitable pretreatment methods
Typical data output
Element identification, elemental concentrations, calibration curves, spectra, and analytical results
Typical applications
Raw material analysis, metal impurity testing, formulation research, and quality control What Is ICP-OES (Inductively Coupled Plasma Optical Emission Spectrometry)?
ICP-OES stands for Inductively Coupled Plasma Optical Emission Spectrometry. It is also commonly referred to as ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometry).
ICP-OES identifies and quantifies elements by measuring the characteristic light emitted by atoms or ions excited in an inductively coupled plasma.
Each element has characteristic emission lines. The instrument separates emitted light by wavelength and measures the intensity of selected spectral lines. Within an appropriate calibration range, emission intensity is related to the concentration of the target element.
How Does ICP-OES Work?
Sample Preparation: Solid or liquid samples are prepared and converted into a suitable solution for analysis.
Nebulization: The sample solution is converted into an aerosol through the sample introduction system.
Plasma Excitation: The aerosol enters a high-temperature argon plasma, where analytes are atomized, excited, and ionized.
Emission Generation: Excited atoms or ions emit light at characteristic wavelengths as they return to lower energy states.
Optical Detection: The optical system separates emission lines, and the detector records their intensities.
Quantitative Analysis: Calibration curves prepared from standard solutions are used to calculate elemental concentrations.
Result Calculation: Sample mass, digestion volume, dilution factors, and blank results are used to calculate elemental content in the original sample. Which Elements Can Be Analyzed by ICP-OES?
ICP-OES can be used to analyze a wide range of metallic elements and selected non-metallic elements.
Element Category
Representative Elements
Alkali metals
Li, Na, K
Alkaline earth metals
Mg, Ca, Sr, Ba
Transition metals
Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn
Precious metals and related elements
Ag, Au, Pt, Pd
Heavy metals and selected hazardous elements
Pb, Cd, Hg, As, Sb, Bi
Refractory metals
Mo, W, Ta, Nb, Zr, Hf
Rare earth elements
La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Yb, Lu, Y
Selected non-metallic elements
P, S, Si, B, Se, etc.
Note: These are representative examples of elements that may be analyzed by ICP-OES. Actual applicability depends on instrument configuration, spectral lines, sample matrix, concentration range, and method validation.
H2: What Can ICP-OES Measure? Typical Applications of ICP-OES Testing
ICP-OES is primarily used for qualitative and quantitative elemental analysis. It supports material composition characterization, metal impurity testing, inorganic component analysis, and selected elemental quality-control applications.
- Metal Element Content Analysis
Determine the concentrations of one or multiple metallic elements to support material composition analysis and quality control.
Typical applications:
Elemental composition analysis of metals and alloys;
Metal content determination in inorganic powders;
Elemental analysis of chemical raw materials;
Residual metal analysis in polymer materials;
Metallic component analysis in composite materials.
- Trace and Low-Level Metal Impurity Analysis Determine selected metal impurities in materials to support raw material purity evaluation and product quality control.
Typical applications:
Metal impurity testing in high-purity chemicals;
Catalyst residue analysis in fine chemicals;
Residual metal catalyst analysis in polymers;
Impurity element analysis in ceramic powders and functional materials;
Selected metal element analysis in biomaterials.
Note: Trace analysis capability depends on the target element, sample matrix, and sample preparation. For extremely low concentrations or ultra-trace analysis, ICP-MS may be more appropriate.
- Inorganic Filler and Functional Element Analysis
Determine selected elemental concentrations to support the characterization of inorganic fillers, functional components, and material formulations.
Typical applications:
Elemental analysis of inorganic fillers in plastics and rubber;
Metallic component analysis in polymer composites;
Elemental composition studies of ceramic materials;
Inorganic element analysis of coatings;
Functional powder and additive characterization. 4. Heavy Metal and Selected Hazardous Element Testing
Determine selected elements such as lead, cadmium, arsenic, chromium, and nickel to support material quality control and relevant compliance assessments.
Typical applications:
Selected heavy metal analysis in chemical raw materials;
Hazardous element analysis in inorganic powders;
Metal element testing in plastics and rubber;
Target element analysis in ceramics and composites;
Raw material supplier quality evaluation. 5. Raw Material and Batch Consistency Analysis
Compare elemental concentrations across multiple batches using consistent sample preparation and analytical conditions.
Typical applications:
Raw material supplier screening;
Elemental composition comparison between product batches;
Manufacturing process consistency evaluation;
Formulation comparison before and after adjustment;
QA/QC quality control.
- Catalyst and Functional Material Analysis
Determine active metals, promoters, and other target elements in catalysts and functional materials.
Typical applications:
Metal loading analysis in catalysts;
Precious metal and transition metal determination;
Dopant analysis in functional ceramics;
Metal element analysis in battery-related materials;
Elemental composition evaluation of advanced functional materials.
- Elemental Mass Balance and Process Research
Compare elemental concentrations in raw materials, intermediates, and finished products to investigate elemental introduction, loss, or residue during processing.
Typical applications:
Material preparation process optimization;
Metal recovery studies;
Catalyst elemental analysis before and after use;
Elemental mass balance between raw materials and final products;
Material purification and impurity removal evaluation. H2: What Materials Can Be Tested by ICP-OES?
ICP-OES is suitable for a wide range of materials that can be converted into stable solutions through appropriate sample preparation.
Jituotech's ICP-OES testing services cover the following material categories:
Material Category
Typical Analytical Applications
Polymers
Residual metal catalysts, inorganic elements, additive-related elements
Plastics and rubber
Metal elements, inorganic filler-related elements, heavy metals
Chemical materials
Raw material composition, metal impurities, catalyst residues
Inorganic ceramics
Major metal elements, dopants, impurity elements
Metals and alloys
Multi-element composition, alloying elements, impurities
Composite materials
Matrix- and filler-related elements, metallic components
Fine chemicals
Metal impurities, catalyst residues, target element concentrations
Biomaterials
Selected metals and inorganic elements
Functional powders
Elemental composition, dopant elements, impurities
Catalysts and additives
Active metals, promoters, and other target elements
How Does Sample Preparation Differ Between Materials?
ICP-OES generally requires samples to be introduced as suitable solutions. Different material systems require different sample preparation methods.
Sample Type
Typical Sample Preparation Approach
Water-soluble chemicals
Appropriate dissolution, dilution, and filtration where necessary
Metals and alloys
Acid digestion using an acid system suitable for the alloy composition
Ceramics and inorganic powders
Acid digestion or another suitable pretreatment depending on acid resistance
Plastics and rubber
Usually require digestion or ashing before solution analysis
Polymers and composites
Digestion procedures developed according to polymer matrices and fillers
Fine chemicals
Dissolution or digestion based on solubility and matrix interference
Biomaterials
Appropriate digestion based on organic matrix composition and target elements
Which Samples May Require Special Assessment Before ICP-OES Testing?
The following samples require a feasibility and safety assessment:
Samples that cannot be effectively dissolved or digested using available preparation methods;
Samples containing large quantities of insoluble particles that prevent representative solution preparation;
Samples that may cause severe matrix interference or instrument contamination;
Samples containing high concentrations of acids, salts, or organic solvents beyond the compatible range of the sample introduction system;
Samples that may release toxic, flammable, or corrosive gases during digestion;
Samples requiring chemical speciation rather than total elemental analysis.
For refractory ceramics, silicates, precious metal alloys, and specialized composites, please provide sample composition information before submission so that an appropriate digestion strategy can be evaluated.
H2: ICP-OES Instrument Model
Jituotech's ICP-OES testing service uses an Agilent 5110 Inductively Coupled Plasma Optical Emission Spectrometer.
Instrument Brand: Agilent
Instrument Model: Agilent 5110 ICP-OES
Instrument Type: Inductively Coupled Plasma Optical Emission Spectrometer
The Agilent 5110 ICP-OES excites elements in a high-temperature argon plasma and detects their characteristic emission lines. It is used for qualitative and quantitative multi-element analysis.
Depending on the instrument configuration, the Agilent 5110 series supports different plasma viewing configurations, including radial and vertical dual-view configurations. The actual viewing mode should be confirmed according to the laboratory's installed equipment.
Image suggestion:
H2: ICP-OES Instrument Technical Specifications
The following information is compiled from Jituotech's existing ICP-OES service page and Agilent 5110 technical documentation.
Technical Parameter
Published Information or Reference
Instrument brand
Agilent
Instrument model
5110 ICP-OES
Analytical technique
Inductively coupled plasma optical emission spectrometry
Detector
VistaChip II CCD (model technical documentation)
Wavelength range
167–785 nm (model technical documentation)
Signal stability
Typically less than 1% RSD over 8 hours without internal standardization or drift correction
Sample type
Liquid samples and solid samples after appropriate preparation
Analytical capability
Qualitative and quantitative multi-element analysis
Typical Analytical Wavelengths and Spectral Resolution
Representative wavelengths and spectral resolution values for the Agilent 5110 are listed below.
Element
Symbol
Wavelength (nm)
Typical Resolution FWHM (pm)
Arsenic
As
188.980
<7
Molybdenum
Mo
202.032
<7
Zinc
Zn
213.857
<7.5
Lead
Pb
220.353
<8
Chromium
Cr
267.716
<9.5
Copper
Cu
327.395
<13
Barium
Ba
614.171
<34
Notes:
These wavelengths and resolution values are representative technical specifications for the Agilent 5110.
Actual analytical wavelengths should be selected according to emission-line characteristics, sample matrix, spectral interference, and concentration range.
Spectral resolution is not equivalent to an elemental detection limit or quantification limit.
The "1 ppm" parameter mentioned on the original service page should be technically verified before publication. It should not be presented as a universal detection limit for all elements.
Actual analytical performance depends on instrument configuration, sample preparation, method parameters, and quality-control results.
H2: ICP-OES Sample Requirements
Appropriate sample preparation helps ensure representative results, analytical accuracy, and testing safety.
Item
Sample Requirements
Sample form
Solid or liquid
Sample quantity
100 mg–5 g as recommended on the original service page; confirm according to material type and preparation method
Sample homogeneity
Samples should be representative and well mixed; powders and particles should be homogenized where appropriate
Packaging
Use clean, sealed containers compatible with the sample
Solubility
The original service page recommends complete dissolution in suitable inorganic solvents or acid systems
Sample information
Provide sample name, major components, target elements, and expected concentration range
Safety information
Disclose corrosive, toxic, flammable, or other hazardous properties
What Information Should Be Provided Before ICP-OES Testing?
To establish an appropriate testing program, customers are encouraged to provide:
Sample name and material category;
Main chemical components or known formulation;
Target elements to be analyzed;
Expected concentration range of each target element;
Sample solubility and known acid resistance;
Required testing standards, if applicable;
Whether a formal report, raw data, or spectral plots are required;
Whether the results are intended for R&D comparison, quality control, or compliance assessment.
Can Solid Samples Be Tested Directly by ICP-OES?
Ordinary solid samples are generally not introduced directly into conventional solution-based ICP-OES systems without appropriate pretreatment.
Solid samples usually require dissolution, acid digestion, microwave digestion, fusion, or another suitable preparation method to transfer target elements into a compatible solution.
Refractory ceramics, silicates, and specialized metal materials may require specific digestion procedures. Incomplete digestion can result in underestimated elemental concentrations.
H2: ICP-OES Testing Process
Jituotech's ICP-OES testing process includes sample information review, preparation method development, instrumental analysis, data calculation, and report review.
- Testing Requirement Consultation
Confirm sample category, target elements, expected concentration range, testing objectives, and reporting requirements.
- Sample Assessment
Evaluate sample homogeneity, solubility, matrix composition, and safety to determine whether ICP-OES analysis is suitable.
- Sample Preparation
Select an appropriate dissolution, acid digestion, microwave digestion, or other preparation method to transfer target elements into a suitable solution.
- Standard Solution and Calibration Curve Preparation
Prepare elemental standards within the appropriate concentration range and establish calibration curves. Blanks and quality-control samples are included where required.
- Instrumental Analysis
Introduce the prepared sample solution into the ICP-OES instrument and measure the characteristic emission lines of the target elements.
- Data Analysis and Result Calculation
Calculate elemental concentrations using calibration data, sample mass, digestion volume, dilution factors, and blank results.
- Data Review and Report Delivery
Review analytical results and quality-control data, then deliver elemental concentrations, relevant spectra, and testing reports according to the agreed project requirements.
ICP-OES Testing Workflow Diagram
flowchart TD A[Testing Requirement Consultation] --> B[Sample and Target Element Confirmation] B --> C[Sample Composition and Safety Assessment] C --> D{Suitable for ICP-OES?} D -->|No| E[Evaluate Alternative Preparation or Analytical Method] E --> B D -->|Yes| F[Develop Sample Preparation Method] F --> G[Sample Dissolution or Acid Digestion] G --> H[Standard Solution and Calibration Curve Preparation] H --> I[ICP-OES Instrumental Analysis] I --> J[Emission Spectrum Acquisition] J --> K[Elemental Concentration Calculation] K --> L[Quality Control and Data Review] L --> M[Testing Report Delivery]
H2: ICP-OES Testing Standards
ICP-OES testing standards should be selected according to sample type, target elements, and analytical objectives. Sample digestion, instrument conditions, and calculation procedures may differ between material systems.
The following are relevant reference standards and methods:
Standard
Standard Title
Typical Application
ISO 19050:2021
Rubber, raw, vulcanized — Determination of metal content by ICP-OES
Determination of major and trace metal contents in raw and vulcanized rubber
ISO 11885:2007
Water quality — Determination of selected elements by ICP-OES
Determination of selected elements in water
EPA SW-846 Method 6010D
Inductively Coupled Plasma-Optical Emission Spectrometry
Multi-element analysis of appropriately prepared samples
ASTM D5185
Standard Test Method for Multielement Determination of Used and Unused Lubricating Oils and Base Oils by Inductively Coupled Plasma Atomic Emission Spectrometry
Multi-element analysis of lubricating oils and base oils; confirm the current edition and scope before use
Standard Applicability Notes
ISO 19050:2021: Covers determination of major and trace metal contents in raw and vulcanized rubber by ICP-OES.
ISO 11885:2007: Primarily addresses selected elements in different types of water and also covers digested sludge and sediment samples.
EPA Method 6010D: Describes multi-element analysis by ICP-OES. Sample preparation should be appropriate for the target elements and sample matrix.
ASTM D5185: Addresses multi-element analysis of lubricating oils and base oils. Specific sample scope and analytes should be confirmed against the standard text.
Note: These standards are references and should not be applied indiscriminately to all materials. Before testing, confirm sample type, standard scope, preparation conditions, target analytes, and laboratory capability.
Important: ISO 22125-2 is related to ICP-MS and should not be listed as an ICP-OES testing standard.
H2: ICP-OES vs. Other Elemental Analysis Techniques
ICP-OES, ICP-MS, AAS, and XRF are all used for elemental analysis, but they differ in analytical principles, sensitivity, sample preparation requirements, and application scope.
Comparison of ICP-OES, ICP-MS, AAS, and XRF
Technique
Full Name
Analytical Principle
Main Advantages
Typical Applications
ICP-OES
Inductively Coupled Plasma Optical Emission Spectrometry
Measures characteristic light emitted by excited elements in plasma
Multi-element analysis, relatively high throughput, broad elemental coverage
Metal content, material composition, impurity analysis
ICP-MS
Inductively Coupled Plasma Mass Spectrometry
Measures ions according to their mass-to-charge ratio
Generally lower detection limits, suitable for ultra-trace and isotope analysis
Ultra-trace metals and isotope analysis
AAS
Atomic Absorption Spectrometry
Measures absorption of characteristic light by ground-state atoms
Established analytical technique for selected elements
Metal and selected heavy metal analysis
XRF
X-ray Fluorescence Spectrometry
Measures characteristic fluorescent X-rays emitted after X-ray excitation
Rapid solid-sample screening; non-destructive testing in suitable applications
Metals, minerals, ceramics, and solid material screening
What Is the Difference Between ICP-OES and ICP-MS?
ICP-OES measures characteristic light emitted by excited elements, while ICP-MS detects ions according to their mass-to-charge ratios.
In general:
ICP-OES is suitable for multi-element analysis of major, minor, and selected trace elements.
ICP-MS is generally more suitable for ultra-trace elemental analysis.
ICP-OES can be a practical choice when target element concentrations are relatively high.
ICP-MS or another appropriate technique should be considered for isotope ratio and isotope composition studies.
The final selection should consider target elements, expected concentrations, sample matrix, detection limits, and project requirements.
What Is the Difference Between ICP-OES and XRF?
ICP-OES generally requires samples to be dissolved or digested before solution analysis. XRF can analyze suitable solid samples directly.
ICP-OES: Suitable for quantitative multi-element analysis of prepared solutions. Results depend on digestion efficiency and solution matrix effects.
XRF: Suitable for rapid elemental screening and selected quantitative analysis of solid materials, often without complete sample digestion.
ICP-OES may be preferred when solution-based quantitative results are required, while XRF can be considered for rapid elemental screening of solid materials.
H2: Three Typical ICP-OES Testing Case Studies
The following are representative application examples developed to illustrate ICP-OES testing strategies, sample preparation, and data interpretation. They are not disclosed Jituotech client projects or actual customer test reports. For final website publication, they should be replaced with anonymized real projects and verified analytical data.
Case Study 1: Elemental Composition and Impurity Analysis of Inorganic Ceramic Powders
Test Sample:
Oxide ceramic powders or functional inorganic powders.
Testing Objectives:
Determine major metallic element concentrations;
Analyze trace metal impurities in raw materials;
Compare elemental composition between different powder batches;
Support ceramic formulation development and raw material quality control.
Testing Method:
Select an appropriate pretreatment method according to the sample composition and acid solubility.
Weigh and digest the sample to transfer target elements into solution.
Prepare elemental standard solutions and establish calibration curves.
Measure characteristic emission lines using ICP-OES.
Calculate elemental concentrations based on sample mass, digestion volume, and dilution factors.
Data and Spectra Obtained:
Characteristic emission spectra of target elements;
Calibration curves and related calibration data;
Concentrations of target elements;
Calculated elemental mass fractions in the original sample;
Elemental composition comparison between batches.